Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. oftalmol ; 77(1): 30-33, jan.-fev. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-899109

ABSTRACT

Resumo Objetivo: Analisar dados clínicos, terapêuticos e parâmetros tomográficos dos pacientes portadores de ceratocone atendidos na Fundação Hilton Rocha. Métodos: É um estudo retrospectivo com amostra aleatória de 150 pacientes submetidos a tomografia de córnea e segmento anterior (Pentacam - Oculus, Wetzlar, Alemanha) na Fundação Hilton Rocha no ano de 2015. Os pacientes foram classificados como portadores ou suspeitos de ceratocone através dos parâmetros: paquimetria, elevação central anterior e posterior, Ambrosio Relational Thinnest (ART), valor de D e ceratometria. Após a seleção foi realizada análise dos prontuários, coletados dados clínicos e terapêuticos dos pacientes. Os dados foram colocados em tabela e analisados. Resultados: Dos pacientes classificados como portadores de ceratocone, 23% tinham 6 parâmetros alterados, e 10% foram classificados com apenas 1 parâmetro alterado. O índice ART foi o que mais se alterou (83%) nos pacientes portadores de ceratocone. Na análise dos dados clínicos e terapêuticos, 76,8% dos pacientes apresentaram acuidade visual melhor ou igual a 20/60, e 19% mencionaram apresentar atopia e, 90% dos pacientes utilizavam como tratamento apenas lentes corretoras (óculos e lente de contato). Conclusão: A utilização de índices tomográficos para o diagnóstico do ceratocone têm aumentado a sensibilidade e a especificidade na triagem de pacientes portadores desta ectasia, possibilitando o diagnóstico de maneira mais precoce e consequentemente maior sucesso terapêutico.


Abstract Objective: Analyze clinical data, therapy and tomographic parameters of patients attended at Fundação Hilton Rocha. Methods: This essay is a retrospective study based on a random sample of 150 patients submitted to cornea tomography and previous segment (Pentacam - Oculus, Wetzlar, Germany) at Fundação Hilton Rocha in the year 2015. The patients were classified as carriers or suspects of keratoconus through the following parameters: pachymetry, anterior and posterior central elevation, Ambrosio Relational Thinnest (ART), value of D and keratometry. After the selection an analysis of the medical records was done, followed by harvest of clinical and therapeutical data of the patients. The data was put on table and then analyzed. Results: From the numbers of the patients diagnosed with carriers of keratoconus, 23% had 6 altered parameters, and 10% were classified with only 1 altered parameter. The ART index was the one that suffered the largest change (83%) on the keratoconus carriers. After analysis of clinical and therapeutical data, 76.8% of patients showed better or more of 20/60 degree of visual acuity, and 19% mentioned signs of atopy, 90% of the patients were using only corrective lenses as treatment (glasses and contact lenses). Conclusion: The use of tomographic indexes for the diagnosis of keratoconus has been increasing the sensibility and specificity of the triage of carriers of this ecstasy, allowing an earlier and better diagnosis of this medical condition.


Subject(s)
Humans , Tomography/methods , Cornea/diagnostic imaging , Keratoconus/diagnosis , Anterior Eye Segment/diagnostic imaging , Visual Acuity , Retrospective Studies , Sensitivity and Specificity , Contact Lenses , Corneal Topography , Dilatation, Pathologic , Eyeglasses , Corneal Pachymetry , Slit Lamp Microscopy , Keratoconus/therapy
SELECTION OF CITATIONS
SEARCH DETAIL